Dometic Micro P-711 Circuit Board by Dinosaur (MICROP-711)
Heavy-duty, fused circuit board fits the following Dometic models NDR 1062, NDR 1272, NDR 1282, NDR 1292, NDR 1492, RM2551, RM2554, RM2607, RM2611, RM2612, RM2620, RM2652, RM2807, RM2811, RM2812, RM2820, RM2852, RM3607, RM3662, RM3663, RM3807, RM3862, RM3863, RM4872, RM4873, RM7030 (Product #921890401), RM7130, RM7732, RM7832, S1521, S1531, S1621, S1631, S1821, S1831.
REPLACES ONLY BOARDS WITH PART NUMBERS BEGINNING WITH "293".
Quality circuit board construction with plated and soldered-through connections features built-in adjustable thermostat, surge protection, improved circuitry to eliminate ground problems common in Dometic refrigerators. 3-year manufacturer’s warranty.
All service parts are non-returnable when opened.
*If the part is defective, the part will be taken care of under warranty by Dinosaur Electronics.
Troubleshooting
Potential problems that a new power board could solve:
- Refrigerator not sensing AC power
- Refrigerator not sensing AC heating element
- Refrigerator not sensing a flame
- Refrigerator not powering on
- Refrigerator incapable of resetting
- Intermittent issues
- If any electrical burn marks are present anywhere on front or back of power board, you should replace it.
Installation
Time:
- 30 minutes or less
Tools:
- Ratchet set
- Screwdriver
Steps:
- Turn your battery switch to OFF
- Remove power board cover
- Take a picture of the board before disconnecting any wires
- Disconnect all wires and remove defective board
- Place new board on old board cover base and connect wires
- Before placing board cover on, turn battery switch ON and power up refrigerator to verify everything is connected and that there are no faults present. If everything is working, put cover back on.