Dometic SR1 Circuit Board for Dometic Servel Refrigerators by Dinosaur
Dinosaur SR1 Board for Dometic®/Servel® Refrigerators
Use in Dometic®/Servel® Models: S520, S530, S619, S620, S630, S819, S820 & S830
- 2 or 3-way operation
- AC / DC / Gas *Fuse protected
- 3.35" x 4.50"
Troubleshooting
Potential problems that a new power board could solve:
- Refrigerator not sensing AC power
- Refrigerator not sensing AC heating element
- Refrigerator not sensing a flame
- Refrigerator not powering on
- Refrigerator incapable of resetting
- Intermittent issues
- SR code display
- If any electrical burn marks are present anywhere on front or back of power board, you should replace it.
Installation
Time: 30 minutes or less
Tools:
- Ratchet set
- Screwdriver
Steps:
- Turn your battery switch to OFF
- Remove power board cover
- Take a picture of the board before disconnecting any wires
- Disconnect all wires and remove defective board
- Place new board on old board cover base and connect wires
- Before placing board cover on, turn battery switch ON and power up refrigerator to verify everything is connected and that there are no faults present. If everything is working, put cover back on.