Norcold N7X/ N8X Flashing Three Times / Limit Circuit Fault (quick fix!)
FLASH PATTERN 3
Norcold N7X / N8X Limit Circuit Fault
The red light flashes three times, goes off for 5 seconds and repeats. A limit circuit on the main control board (power board assembly) is open. The fix is a new power board.
Before you start
- Note the code. Count the flashes twice to be sure it’s 3 and not 2 or 4. Those point to different faults.
- Stay safe. Turn the fridge OFF and unplug it from 120V and 12V before removing the board.
STEP 1
Reset the fridge once
Turn the fridge OFF, then back ON. This clears the code so you can see if it comes back.
Does the 3-flash code come back?
Solved for now
The code cleared. If 3 flashes return, the limit circuit on the board has opened again. Replace the board.
Replace the power board
The limit circuit is part of the main control board (power board assembly). NorcoldIt can’t be repaired on its own, so the fix is a new board.#8217;s fix for this code is a new board.
Norcold Power Board 639593 →Main control board for the Polar N7X and N8X.Based on the Norcold Polar N7V/N7X/N7LX/N8V/N8X/N8XL service manual, Fault Code Flash Pattern 3.