Norcold 2118 no AC, no FL Code

15th Oct 2026

Norcold 2118 no AC, no FL Code

code

no AC no FL

Norcold 2118 no AC, no FL Code

Two faults at once, in AUTO mode: AC dropped below 85 volts, so the fridge switched to propane, and then the burner wouldn’t light.

Before you start

  • Good voltage is 10.5 to 15.4 volts DC for the controls and 108 to 132 volts AC for the heaters.
  • Where things are. The power board, fuses, burner, gas valve and the Temperature Monitor Control (TMC) are behind the lower outside vent. The display and buttons are at the top front of the fridge.

Fits these models

21182118SS2118BK2118IM2118IMSS2118IMBK2118IMD2118SSIMD2118IMDBK

The Norcold 2118 four-door, 2-way (120V AC and propane) refrigerator, including the IM (ice maker) and IMD (ice maker and dispenser) versions.

What you’ll see

code

The display cycles through no AC, then no FL, while the alarm beeps.

STEP 1

Fix the AC side

Work through no AC: the outlet, the cord and fuse F2.

▼
?

Did that fix the AC?

YES
▼

Half done

It’ll run on AC again. Still fix the gas side so it can switch over.

NO
▼
Go to Step 2 ▼

STEP 2

Fix the gas side

Work through no FL: gas supply, burner, electrode, pressure and the gas valve.

▼
?

Do both check good?

NO
▼

Repair what you found

Fix the AC and gas problems you found.

YES
▼

Replace the power board

Both power sources are fine, so the board is at fault. It’s behind the lower outside vent, under a cover on the back of the fridge. See Norcold 2117 / 2118 parts or ask a tech to confirm the right board.

← All 2118 codes   2117 / 2118 parts   Parts diagrams
Still stuck? ask a tech with your model, serial number and the code you’re seeing. We’ll confirm the part before you order.
Covers the Norcold 2118, 2118SS, 2118BK, 2118IM, 2118IMSS, 2118IMBK, 2118IMD, 2118SSIMD and 2118IMDBK. Based on the Norcold 2118 service manual (637026 Rev. B), fault code no AC, no FL.