Norcold 2118 FL -- Code (Flame With Gas Off)

15th Oct 2026

Norcold 2118 FL -- Code (Flame With Gas Off)

code

FL --

Norcold 2118 FL -- Code (Flame With Gas Off)

The power board sensed a flame when the gas should be off. The gas valve is mechanically stuck open. This code can show in any mode.

Before you start

  • Where things are. The power board, fuses, burner, gas valve and the Temperature Monitor Control (TMC) are behind the lower outside vent. The display and buttons are at the top front of the fridge.
  • Safety first. Turn off the propane at the tank until the valve is replaced.

Fits these models

21182118SS2118BK2118IM2118IMSS2118IMBK2118IMD2118SSIMD2118IMDBK

The Norcold 2118 four-door, 2-way (120V AC and propane) refrigerator, including the IM (ice maker) and IMD (ice maker and dispenser) versions.

What you’ll see

code

FL then --. The code alternates between its two halves while the alarm beeps.

STEP 1

Shut off the propane

Close the valve at the propane tank. The fridge can still run on 120V AC in MANUAL AC mode.

▼

Replace the gas valve

Norcold’s fix for FL -- is a new gas valve. Leak test every connection afterward with soapy water. The original 2118 gas valve is discontinued, so ask a tech for the current replacement.

← All 2118 codes   2117 / 2118 parts   Parts diagrams
Still stuck? ask a tech with your model, serial number and the code you’re seeing. We’ll confirm the part before you order.
Covers the Norcold 2118, 2118SS, 2118BK, 2118IM, 2118IMSS, 2118IMBK, 2118IMD, 2118SSIMD and 2118IMDBK. Based on the Norcold 2118 service manual (637026 Rev. B), fault code FL --.