Norcold 1200 / 1210 Sr Code (Flame Sensing Malfunction)
Sr CODE
Norcold 1200 / 1210 Sr Code (Flame Sensing Malfunction)
The display shows Sr. The power board found a problem in its own flame sensing or gas valve circuits. Norcold’s fix for this code is a new power board.
Before you start
- What sets it. Any of these, in any mode: a problem in the flame sense circuitry; the gas valve being powered when it shouldn’t be; the gas valve not being powered when it should be; or an internal memory fault.
- Fault history. It’s saved about 25 seconds later on diagnostic screen 5, segment 5.
- Not the same as no FL. If the display alternates no and FL, the burner didn’t light, and that has its own checks. See the no FL flowchart.
STEP 1
Reset the fridge once
Turn the fridge OFF, then back ON, and let it run on LP.
Does Sr come back?
Solved for now
The code cleared. If Sr returns, the board’s flame sense circuit is failing. Replace the power board.
STEP 2
Check for AC ripple
Before you replace the board, check the 12V DC supply for AC ripple. AC ripple on the DC lines can damage the power board and cause the Sr code, and even 0.05 VAC is enough. Plug into shore power so your inverter/charger or converter is running, set your multimeter to AC volts, and measure across the 12V DC terminals at the fridge’s power board.
Do you read 0.05 VAC or more?
Replace the inverter/charger or converter
The AC ripple is coming from your inverter/charger or converter. Replace it before you replace the board, or a new board can fail the same way. Then reset the fridge and check if the Sr code comes back.
Shop RV Inverters & Converters →Replacement inverter/chargers and converters.Replace the power board
The flame sensing circuit is part of the power board. Pick the board that matches your serial number:
Norcold Power Board 628661 →OEM board for every 1210, and 1200s with serial 8981139 and above.
Norcold Upgraded Power Board (Dinosaur) 6212XX →For older 1200s with serial 8981138 and below.Still stuck? ask a tech with your model, serial number and the readings you got. We’ll confirm the part before you order.
Based on the Norcold 1200/1210 service manual, Sr Code (Flame Sensing Malfunction).