Norcold 2118 AC rE Code (AC Relay Stuck Closed)

15th Oct 2026

Norcold 2118 AC rE Code (AC Relay Stuck Closed)

code

AC rE

Norcold 2118 AC rE Code (AC Relay Stuck Closed)

The contacts of relay K2 on the power board, which switch the AC heaters, are stuck closed. The heaters could stay on. This code can show in any mode.

Before you start

  • Where things are. The power board, fuses, burner, gas valve and the Temperature Monitor Control (TMC) are behind the lower outside vent. The display and buttons are at the top front of the fridge.

Fits these models

21182118SS2118BK2118IM2118IMSS2118IMBK2118IMD2118SSIMD2118IMDBK

The Norcold 2118 four-door, 2-way (120V AC and propane) refrigerator, including the IM (ice maker) and IMD (ice maker and dispenser) versions.

What you’ll see

code

AC then rE. The code alternates between its two halves while the alarm beeps.

STEP 1

Turn it off and unplug it

Turn the fridge off and unplug the AC cord so the heaters can’t stay on.

▼

Replace the power board

The stuck relay is part of the power board. It’s behind the lower outside vent, under a cover on the back of the fridge. Ask a tech if you’re not sure it’s the board.

Norcold Power Board 637082 / 636852 Norcold Power Board 637082 / 636852 →The 2118 power board. Fits all 2118 models.
← All 2118 codes   2117 / 2118 parts   Parts diagrams
Still stuck? ask a tech with your model, serial number and the code you’re seeing. We’ll confirm the part before you order.
Covers the Norcold 2118, 2118SS, 2118BK, 2118IM, 2118IMSS, 2118IMBK, 2118IMD, 2118SSIMD and 2118IMDBK. Based on the Norcold 2118 service manual (637026 Rev. B), fault code AC rE.