CODE E4

Norcold N8DC and N10DC Error Code E4: Door Left Open

The fresh food door has been open for more than 2 minutes, or the board thinks it has. If the door is shut, look at the door switch wiring and the board.

Before you start

    Fits these models

    N8DCN8DCXN10DCN10DCX

    Norcold’s 12V DC compressor refrigerators (8.2 and 9.7 cu ft). These run on 12 volts only: no propane, no 120V heater.

    What you’ll see

    E4 in the MODE window on the front touch panel. The board thinks the fresh food door has been open more than 2 minutes.

    STEP 1

    Close the door

    Make sure the fresh food door is fully closed and latched.

    ▼
    ?

    Is E4 gone?

    YES
    ▼

    You’re done

    The door just wasn’t fully shut.

    NO
    ▼
    Go to Step 2 ▼

    STEP 2

    Check the board connections

    Check every plug on the user interface control board against the wiring diagram, including the interior light switch.

    ▼
    ?

    Is everything connected correctly?

    NO
    ▼

    Reconnect the plugs

    Push each harness into its matching header. If E4 is still there, replace the board.

    YES
    ▼

    Replace the user interface control board

    It’s the control board behind the touch panel at the top of the fridge. See the N8DC or N10DC parts or ask a tech.

    ← All N8DC / N10DC codes   N8DC parts   N10DC parts   Parts diagrams
    Still stuck? ask a tech with your model, serial number and the code or readings you got. We’ll confirm the part before you order.
    Covers the Norcold N8DC, N8DCX, N10DC and N10DCX. Based on the Norcold N8DCX/N10DCX service manual (640083D), fault code E4.